How to Delete Sensor on GE Simon XT Alarm

How to Delete Sensor on GE Simon XT
How to Delete Sensor on GE Simon XT
Do you want to delete a sensor you no longer use?  Do you have a bad sensor you want to delete?  Follow my detailed step-by-step instructions to delete a sensor on a GE Simon XT Alarm…

How to Delete Sensor on GE Simon XT Alarm

Hardware:

Step 1: Press the down arrow (below the OK) until the screen says “System Programming” and then press the “Ok” button.

The “System Programming” menu on a GE Simon XT

Step 2: Enter the programmers 4-digit access code and press the “Ok” button.

This is not the code you use to arm the alarm but a separate code for setting up the alarm.  If you don’t know it talk to the company you purchased the alarm from.  The alarm will not tell you that you entered an incorrect password–if the menu you are looking for isn’t there after you enter the code, you’ve likely entered the wrong code.

You must know the programmer’s code to delete a sensor

Step 3: Press the down arrow until the screen says “Sensors” and then press the “Ok” button.

The sensor programming section on a Simon XT

Step 4: Press the down arrow once and the screen will say “Delete Sensor.”  Press the “Ok” button.

The “Delete Sensor” menu section on a Simon XT

Step 5: Press the down or up arrows to select the sensor you would like to delete and then press the “Ok” button to delete the sensor.

The first sensor it will list will be the CDMA or GSM module:

Sensor 40 is the Alarm’s Wireless radio–don’t delete that 🙂

Did you accidentally delete sensor 40?  No problem, simply power cycle the alarm and it will be back again–no big deal.

Hint:  Press the “Status” button to go back at any time.

All my GE Simon Alarm Posts:

Amazon Associate Disclosure: As an Amazon Associate I earn from qualifying purchases. This means if you click on an affiliate link and purchase the item, I will receive an affiliate commission. The price of the item is the same whether it is an affiliate link or not. Regardless, I only recommend products or services I believe will add value to Share Your Repair readers. By using the affiliate links, you are helping support Share Your Repair, and I genuinely appreciate your support.

Written By
More from John Mueller
How to Fix RedBoard COM Port Does Not Show Up In LINX Firmware Wizard
I purchased a sparkfun Inventor’s kit in order to learn LabVIEW and...
Read More

2 Comments

  • I have a Simon XT. I can get to step 3, but sensors is not one of the choices. My choices are: Access codes, Security, Phone #s, Timers, Siren options, Light control, System tests

    • I believe that is because you are not entering the correct code. You can have a user code and a separate program code. If you enter the programmer code you get all the options.